| Sign In | Join Free | My entremaqueros.com |
|
Brand Name : PX0575/20/63
MOQ : 400
Model Number : PX0575/20/63
Stock : 386
Description : Power Entry Modules (PEM) RoHS
Packaging Details : -
This comprehensive range of IEC connectors, conforming to IEC and EN 60320 specifications, offers quality mains-rated inlets, outlets, and connectors suitable for a wide array of mains-powered equipment and cable applications. With electrical ratings up to 20A and 250V (UL), these connectors are available in various mounting styles and termination options, including flange fixing, snap-to-panel, PCB mounting, and different tab and screw terminal types. Accessories such as insulating boots, retaining clips, and safety covers are also available. Most styles are offered in standard black, white, or grey, with special colors available to match OEM equipment, subject to product approval.
| Product Type / Standard | Model / Sheet No. | Fixing Type | Termination Type | Current Rating | Voltage Rating | Max. Plug Temperature | Operating Temperature Range | Contact Resistance | Insulation Resistance | AC Breakdown |
|---|---|---|---|---|---|---|---|---|---|---|
| IEC 60320-1 (C14) | PX0579, PX0580, PX0590, PX0596, PX0575, PX0595, PF0001, PF0002, PF0030, PF0033, PX0575/10/28, PX0575/10/PC, PX0580/28, PX0579/28, PX0580/PC, PX0580/PC/7, PF0001/48, PF0001/PC, PF0002/28, PF0030/28, PF0030/PC, PF0033/10/28 | Flange Fixing, Snap to Panel, PCB Mounting | 2.8/4.8/6.3mm Tabs, Screw Terminals, PC Spills | 10A | 250V AC (UL/CSA: 15A, 250V AC) | +70C | -40C to +70C | <10m | >10 M | 5kV (Contact-Contact), 4kV (Contacts-Panel/Accessible Parts) |
| IEC 60320-1 (C14) - Fused | PF0001, PF0002, PF0030, PF0033, PF0006, PF0007, PF0011, PF0016 | Flange, Snap to Panel, PCB Mounting | Tabs, Screw Terminals, PC Spills | 10A | 250V AC | +70C | -40C to +70C | <10m (<15m incl. Fuseholder) | >10 M | 5.5kV (Contact-Contact), 4kV (Contacts-Panel) |
| IEC 60320-1 (C14) - Twin Fused | PF0030, PF0033 | Flange, Snap to Panel | Tabs, PC Spills | 10A | 250V AC | +70C | -20C to +70C | <15m (per Contact) | >10 M | 6kV (Contact-Contact), 5kV (Contacts-Panel) |
| IEC 60320-1 (C13, C15, C19) | PX0587, PX0588, PX0597, PX0587/SE, PX0585, PX0686, PX0686/SE, PX0685 | Cable Mounting, Side Entry, Right Angle | Screw Terminals | 10A, 16A | 250V AC | +70C | -40C to +70C | <10m | >10 M / >10 M | 4kV to 6kV |
| IEC 60320-1 (C15 & C16) - Hot Condition | PX0597, PX0590, PX0595 | Flange Mount, Snap Fit to Panel | Tabs, Screw Terminals | 10A | 250V AC (UL/CSA: 15A, 250V AC) | +120C | -40C to +70C | <10m | >10 M | 4.5kV to 10kV |
| IEC 60320-1 (C18) - Class II | PX0690, PX0691, PX0705, PX0725 | Flange Mount, Snap Fit to Panel | Tabs, Screw Terminals, PC Spills | 10A | 250V AC (UL/CSA: 15A, 250V AC) | +70C | -40C to +70C | <10m | >10 M | 4kV to 10kV |
| IEC 60320-1 (C18) - Class II Fused | PF0006, PF0007, PF0016 | Flange Mount, Snap Fit to Panel | Tabs | 10A | 250V AC | +70C | -40C to +70C | <10m (<15m incl. Fuseholder) | >10 M | 5.5kV (Contact-Contact), 4kV (Contacts-Panel) |
| IEC 60320-2-2 (F) - Class I | PX0716, PX0675, PX0695, PX0783, PX0793, PX0793/1 | Snap Fit to Panel, Flange Mount, PC Flange Rear Mount | Tabs, Screw Terminals, PC Spills | 10A | 250V AC (UL/CSA: 15A, 250V AC) | +70C | -40C to +70C | <10m | >10 M | 4kV to 9kV |
| IEC 60320-2-2 (H) - Class II | PX0705, PX0725 | Flange Mount, Snap Fit to Panel | Tabs, PC Spills | 10A | 250V AC (UL/CSA: 15A, 250V AC) | +70C | -40C to +70C | <10m | >10 M | 4kV to 9kV |
| IEC 60320-1 (C19 & C20) - Class I | PX0599, PX0596, PX0598 | Cable Mounting, Flange Mount, Snap Fit to Panel | 6.3mm or 4.8mm Tabs, Screw Terminals | 16A | 250V AC (UL/cUL: 20A, 250V AC) | +70C | -40C to +70C | N/A | >5M / >10 M | 1.5kV AC to 3kV AC |
| Accessory Type | Part Number | Description | Compatible Products |
|---|---|---|---|
| Retaining Clip | KT0006 | Prevents accidental removal of connector. | PX0580 + PX0587, PX0590 + PX0597, PX0690 + PX0587, PX0675 + PX0686, PX0793 + PX0686, PX0793/1 + PX0686 |
| Retaining Clip | KT0009 | Prevents accidental removal of connector. Fits fused flanged inlets. | PF0001 + PX0587, PF0001/PC + PX0587, PF0002 + PX0587, PF0030 + PX0587 |
| Retaining Clip | KT0012 | Prevents accidental removal of connector. | PX0596 + PX0599 |
| Blanking Cover | PNo 14228 | Protects front of outlet connector. Protects against accidental electric shock. | PX0578, PX0675, PX0695, PX0783, PX0793, PX0716 |
| Insulation Boot | PNo 14340 | Protects rear of connector. Protects against accidental electric shock. | PS20, PS21, PS25, PS26 |
| Insulation Boot | PNo 14317 | Protects rear of connector. Protects against accidental electric shock. | PF0030, PF0033 (except /PC versions) |
| Insulation Boot | PNo 11328 | Protects rear of connector. Protects against accidental electric shock. | PX0575, PX0579, PX0580, PX0590, PX0595 |
| Insulation Boot | PNo 11987 | Protects rear of connector. Protects against accidental electric shock. | PF range (PF0001, PF0002, PF0006, PF0007, PF0011, PF0016 - Except /PC versions) |
| Insulation Boot | PNo 12075 | Protects rear of connector. Protects against accidental electric shock. | PX0675, PX0695, PX0705, PX0725, PX0783, PX0793, PX0793/1 (Except /PC versions) |
| Insulation Boot | PNo 14064 | Protects rear of connector. Protects against accidental electric shock. | PX0596, PX0598 |
|
|
Bulgin PX0575/20/63 Images |